Holographic Characterization of Contaminants in Water: Differentiation of Suspended Particles in Heterogeneous Dispersions
Abstract
Determining the size distribution and composition of particles suspended in water can be challenging in heterogeneous multicomponent samples. Light scattering techniques can measure the distribution of particle sizes, but provide no basis for distinguishing different types of particles. Direct imaging techniques can categorize particles by shape, but offer few insights into their composition. Holographic characterization meets this need by directly measuring the size, refractive index, and three-dimensional position of individual particles in a suspension. The ability to measure an individual colloidal particle’s refractive index is a unique capability of holographic characterization. Holographic characterization is fast enough, moreover, to build up population distribution data in real time, and to track time variations in the concentrations of different dispersed populations of particles. We demonstrate these capabilities using a model system consisting of polystyrene microbeads co-dispersed with bacteria in an oil-in-water emulsion. We also demonstrate how the holographic fingerprint of different contaminants can contribute to identifying their source.
keywords:
holographic microscopy, particle characterization, concentration measurement, colloid, emulsion, bacteria1 Introduction
Oil extraction and petroleum refining inevitably generate oily wastewater. With a production in excess of 200 million barrels per day, oily wastewater is the largest waste stream in the global oil and gas industry [12]. Efforts to monitor and mitigate this source of environmental contamination are hindered by the tendency to form long-lived oil-in-water emulsions [20, 19, 47]. Increasingly strict regulation of oil concentration in effluent water [47] creates a need for methods to measure the size distribution and concentration of oil emulsion droplets. In-line and on-line monitoring have a particular need for measurement techniques that do not require post-installation calibration.
Mitigating oil-emulsion pollution by coagulation with microplastic beads creates an alternative risk of environmental contamination by the beads themselves. This compounds the challenge faced by wastewater treatment works of environmental microbeads arising from personal care products [28].
Effectively monitoring the quality of effluent wastewater from oil refining and related industrial activities increasingly requires characterization methods that can differentiate dispersed colloidal particles on the basis of composition and then monitor the concentrations and size distributions of each component [1, 5, 23, 29]. Complex heterogeneous mixtures from industrial and municipal effluents require multiple analytical techniques to identify the presence of different species [22]. For suspended materials in particular, conventional particle-sizing techniques such as dynamic light scattering (DLS) [15, 44], light obscuration (LO) [17, 41], and the Coulter principle [34] offer insights into the distribution of particle diameters in aqueous solutions but are unable to distinguish particles made of different materials. Particle-shape analysis by micro-flow imaging (MFI) [35] similarly cannot differentiate different types of emulsion droplets. Here, we demonstrate that images acquired through in-line holographic video microscopy [36, 6] can be interpreted with the Lorenz-Mie theory of light scattering [4, 27] to measure the sizes and refractive indexes of individual colloidal particles as they flow down a microfluidic channel [7, 9].
The ability to measure the refractive index of individual colloidal particles is a unique benefit of holographic characterization relative to other particle-characterization techniques [43, 6]. Because the refractive index can serve as a proxy for a particle’s composition, this information is useful for differentiating co-dispersed populations of colloidal particles [46]. Simultaneous measurements of size and refractive index enable us to monitor the characteristics of different types of particles independently, and to monitor their concentrations over time.
2 Methods and Materials
2.1 Methods
2.1.1 Holographic characterization
Fig. 1 depicts the principle and workflow of a holographic characterization measurement. The custom-built instrument, shown schematically in Fig. 1(a), illuminates its sample with the collimated beam from a solid-state laser (ThorLabs CPS532, ) operating at a vacuum wavelength of . Light scattered by a particle in the sample interferes with the unscattered portion of the laser beam in the focal plane of a telecentric microscope created with a standard microscope objective lens (Nikon Plan Fluor, , numerical aperture 0.75) and a focal length tube lens. The magnified interference pattern is relayed to a video camera (Allied Vision Mako U-130B) that records its intensity, , with an effective magnification of on a array.
Each video frame constitutes a hologram of the particles in the observation volume at the instant that the image was recorded. The example in Fig. 1(b) is a -wide region of interest cropped from the full field of view showing the experimentally recorded hologram of a polystyrene microbead dispersed in water. Each hologram is fit pixel-by-pixel to predictions of the Lorenz-Mie theory of light scattering to obtain the particle’s instantaneous three-dimensional location, , its diameter, , and its refractive index, , at the imaging wavelength. Fig. 1(c) shows such a fit.
The quality of this typical fit can be appreciated by averaging the hologram over angles to obtain its radial profile, which is plotted as a black curve in Fig. 1(d). The corresponding radial profile of the fit is superimposed as an orange curve. The experimental and theoretical curves agree to well within the instrumental uncertainty, which is indicated by the shaded blue region in Fig. 1(d). Each such fit provides characterization data for a single particle with instrumental uncertainties of in the single-particle diameter and in the refractive index.
Population averages for a sample, such as the example in Fig. 1(e), can be obtained by repeating this process as particles flow through the observation volume. The instrument in Fig. 1(a) is outfitted for this purpose with a microfluidic flow channel (ibidi, -Slide VI Luer Uncoated Microscopy Chamber). This -long channel has an optical path length of . Pressure-driven flows of up to are driven with a syringe pump (New Era Systems, NE-1000) These flows are fast enough to analyze of sample in under , yet slow enough to avoid artifacts due to motion blurring [9, 14] given the camera’s exposure time.
The camera is set to record frames per second, which means that each particle is recorded at least times as it transits the observation volume. The resulting sequence of location measurements is linked into a trajectory for each particle using a maximum likelihood algorithm [11, 9]. Trajectories are used to monitor the flow profile within the channel [9] so that the total volume of analyzed sample is known precisely. The characterization data associated with each trajectory are combined to improve the instrumental precision and accuracy of the single-particle characterization data. Data points in Fig. 1(e) were obtained in this way.
The density of points, , in a scatter plot such as Fig. 1(e) provide insight into the distribution of sizes and particle properties within the sample. The individual data points in Fig. 1(e) are colored according to to avoid ambiguity due to points overlapping and obscuring each other. The data in this plot suggest that this sample has a mean particle diameter of and a mean refractive index of . The former is consistent with the size range certified by the National Institutes of Science and Technology (NIST), as quoted by the manufacturer. The latter is consistent with the range expected for polystyrene spheres [18] at the imaging wavelength, which is plotted as horizontal dashed lines in Fig. 1(e).
The number of individual single-particle characterization results that fall outside the manufacturer’s specification is smaller than would be expected on the basis of simple counting statistics. Our results therefore suggest that the quality of the sample actually surpasses the manufacturer’s specification. Similarly good results are obtained with validation measurements on standard samples with diameters ranging from to and with refractive indexes ranging from to .
Both the number of particles and the volume of sample analyzed are known precisely in a holographic characterization measurement. These data therefore can be used to measure the concentration of particles in suspension. This can be reported as an overall value for the entire sample using the aggregated data in Fig. 1(e). Alternatively, the time sequence of particle detections can be used to monitor fluctuations in particle concentration. Fig. 1(f) shows a series of detections from a measurement. Smoothing these data, as in Fig. 1(g), shows an overall rate of particle detection every in this sample.
2.1.2 Holographic characterization: Lorenz-Mie analysis
The hologram of a colloidal particle recorded by the camera may be modeled as the superposition of the incident illumination, , and the wave scattered by the particle, :
(1) |
We model the illumination’s electric field as a plane wave propagating along and linearly polarized along ,
(2) |
where is the wavenumber of light in a medium of refractive index . The field scattered by a sphere at position then has the form
(3) |
where is the Lorenz-Mie scattering function for a sphere of diameter and refractive index illuminated by an -polarized plane wave. This function is a standard result in the theory of light scattering [4, 27], and can be computed efficiently [42, 45, 33, 30]. Treating the microscope’s focal plane as and normalizing a measured hologram by the illumination’s intensity, , yields
(4) |
We use the Levenberg-Marquardt algorithm [26] to fit this model pixel-by-pixel to the measured hologram by optimizing , and . In practice, we also subtract the camera’s dark count, , from and before computing the normalized hologram. The holograms in Fig. 1(b) and Fig. 1(c) were treated in this way.
2.1.3 Holographic characterization: Calibration
Holographic characterization relies on three calibration constants: the vacuum wavelength of the illumination, the magnification of the optical train, and the refractive index of the fluid medium at the imaging wavelength. The laser wavelength is specified by the manufacturer with part-per-thousand precision, which is sufficient for holographic characterization measurements. The microscope’s magnification of is computed from the magnification of the objective lens, the focal length of the tube lens, and the manufacturer’s specification for the camera’s pixel dimensions. The resulting value is confirmed with a magnification calibration scale (Ted Pella, catalog number 2285-16) These two instrumental parameters can be assessed once and do not require subsequent calibration.
The third sample-dependent parameter can be measured separately, for instance with an Abbe refractometer. No other calibration constants or procedures are required.
2.1.4 Holographic characterization: Operating range, precision and accuracy
Our implementation of holographic characterization works for particles ranging in diameter from to . The lower limit is set by the low signal-to-noise ratio of scattering patterns created by smaller particles. The upper limit is set by the appearance of strong local minima in the five-dimensional error surface for the nonlinear fit. Optimization algorithms based on gradient descent, such as Levenberg-Marquardt, can become trapped in these local minima, and thus yield incorrect results. This limitation may be lifted in future implementations by adopting alternative optimization strategies.
Estimates for , and obtained by fitting measured holograms to Eq. (4) include computed uncertainties in these adjustable parameters. If the reduced statistic for the fit is close to unity, these uncertainties should serve as estimates for the precision in each parameter. Previous studies [6, 9, 21] have confirmed this assessment by measuring the trajectories of freely diffusing colloidal spheres. Random measurement errors contribute a constant additive offset to a trajectory’s mean-squared displacement that can be extracted from the computed results. Such measurements confirm that the precision for measuring a micrometer-scale sphere’s location is in plane and along the optical axis. Agreement between results obtained in each of the three Cartesian coordinates suggests that the measurement’s accuracy is comparable to its precision [21]. Measurements of single-particle sedimentation yield estimates for particles’ hydrodynamic radii that are consistent with holographic estimates, and support an overall precision of in particle diameter [21]. Measurements performed with colloidal spheres dispersed in precision index-matching fluids [37] suggest that the uncertainty in holographic estimates for the refractive index is efractive index units.
Although these error estimates were performed for homogeneous colloidal spheres, comparably good results have been obtained for porous spheres [10], dimpled spheres [16], and randomly branched fractal aggregates [40, 39]. We anticipate, therefore, that holographic characterization will perform comparably well for assessing particle composition characteristics in wastewater analysis and environmental monitoring.
2.1.5 Holographic characterization: Concentration range
The upper range of particle concentrations amenable to holographic characterization is set by the need to avoid excessive overlap between neighboring particles’ holograms. As a rule of thumb, this limit is reached when more than ten particles are in the observation volume at once, and corresponds to a concentration of for our instrument. The lower limit is set by the need for particles to pass through the observation volume during a reasonable measurement period. Requiring particles to pass through during a measurement sets the lower limit of the concentration range to .
2.1.6 Holographic characterization: Aspherical particles
The Lorenz-Mie analysis used for holographic particle characterization presupposes that each particle is a homogeneous, isotropic and smooth sphere. Applying the same analysis to holograms of aspherical and inhomogeneous particles yields results for the diameter and refractive index that can be interpreted with effective medium theory [2]. Specifically, recent studies have demonstrated [39] that holographic characterization of non-ideal particles yields the size of an effective sphere that bounds the particle. The estimated refractive index is the volume-weighted average of the material from which the particle is composed and the medium that fills its pores. This analysis has been shown to yield useful results for dimpled spheres [16], rough spheres [16], porous spheres [10], and aspherical fractal clusters [39, 40].
2.1.7 Dynamic Light Scattering
Dynamic light scattering measurements are performed with a Malvern Zetasizer Nano ZS. Samples are mixed by manual agitation before being transferred to a square polystyrene cuvette (Malvern DTS0012) for measurement. Intensity-averaged particle diameters were calculated from the instrument’s standard cumulant analysis, as defined in ISO13321.
2.2 Materials
2.2.1 Monodisperse colloidal spheres
All of the monodisperse colloidal spheres used for this study were purchased as aqueous dispersions from Bangs Laboratories.
Polystyrene size standards (Catalog Number NT16N) have a NIST-certified diameter of . They were delivered at a volume fraction of . This sample was diluted with deionized (DI) water to a volume fraction of before use.
Three populations of microspheres were combined to create the three-component mixture used for Fig. 2: silica microspheres (Catalog Number SS03N, ); polymethylmethacrylate (PMMA) microspheres (Catalog Number PP03N, ); and polystyrene microspheres (Catalog Number NT12N, ). Each of these samples were delivered at wt/v and were individually diluted with DI water to a concentration of . Equal volumes of the three diluted samples then were mixed to create the three-component sample. The same mixture was used for DLS and holographic characterization measurements. The specified diameter of the PMMA particles was established with dynamic light scattering (DLS). The equivalent values for the silica and polystyrene particles were determined with a combination of photon correlation spectroscopy (PCS) and quasi-elastic light scattering (QELS).
2.2.2 Silicone oil emulsion
Silicone oil was obtained from Dow Corning (SYLGARD 184 Silicone Elastomer, Lot #0008569647). Oil was dispersed in DI water at a concentration of by vortexing for . These samples were then agitated by hand up to the point that the sample was introduced into the instrument for measurement.
2.2.3 E. coli suspension
Escherichia coli is a rod-like bacterium with a cylindrical diameter of about and a length that ranges from to somewhat less than depending on the time since the last cell division [3]. Samples of Escherichia coli K-12 were obtained from Carolina Biological Supply Company and were cultured at in LB Broth obtained from ThermoFisher Scientific. Cultured bacteria were dispersed for study in DI water at at a concentration of .
2.2.4 Crude oil emulsions
Crude oil samples were obtained from ONTA, Inc. (Light Crude Oil Set). Emulsion of these samples were prepared and handled in the same manner as the silicone oil emulsions, at a concentration of .
3 Results and Discussion
3.1 Validation with standard samples
The data in Fig. 1(e) were obtained with a dispersion of NIST-traceable colloidal size standards with a nominal diameter of . This range is indicated by vertical dashed lines in Fig. 1(e). These particles are made of polystyrene, which has a refractive index of at the imaging wavelength, as indicated by horizontal dashed lines. The specified standard deviations in size and refractive index establish a rectangular domain in the plane within which of measured data points are expected to fall. In fact, of the measurements fall within this domain, or . We conclude that the manufacturer’s specification is consistent with the standard deviation of an assumed normal size distribution.
The data in Fig. 2 demonstrate that holographic characterization achieves comparably good results for heterogeneous samples that span a range of refractive indexes. In this case, the sample comprises three populations of monodisperse spheres, all of nearly the same size but composed of different materials. Three peaks are clearly resolved in the joint distribution, , of size and refractive index. The peak positions in this trimodal distribution are marked with plot symbols in Fig. 2 and agree with the manufacturer-specified properties of each of the component populations. Holographic characterization thus successfully differentiates the particles by composition, even when they cannot be differentiated by size.
Fig. 2 also compares results from holographic characterization with results obtained with dynamic light scattering for the same mixed sample. To make this comparison, the joint distribution of size and refractive index measured by holographic characterization is averaged over refractive indexes and distributed into the same diameter bins presented by the commercial DLS software. The trimodal data in the scatter plot therefore appears as a single peak in the relative frequency of particle diameters. This peak coincides well with the peak in the size distribution reported by DLS, thereby providing additional verification of the size data obtained holographically.
DLS offers no basis for differentiating particles by composition. The slight discrepancy in the widths of the peaks can be ascribed to the range in the particles’ refractive indexes, which is not taken into account by DLS. The existence of the underlying trimodal composition could not have been inferred from DLS data, although it is obvious in the holographic characterization results. This, therefore, constitutes a distinctive benefit of holographic characterization for characterizing inhomogeneous samples.
3.2 Concentration measurements
By detecting and characterizing particles one at a time, holographic characterization also lends itself to measuring the concentration of particles and droplets in a suspension. This process could be subject to biases if the ability to detect and count particles somehow depended on the concentration. The data in Fig. 3(a) show the measured concentration of -diameter polystyrene spheres in water over a range of to . Samples were prepared by repeated diluting an initial stock sample by ten-fold increments. Concentrations obtained by holographic characterization agree with the expected values over the entire range of concentrations.
Particle-resolved characterization also has the benefit that characterization results do not depend on particle concentration, even for heterogeneous samples. Fig. 3(b) compares results for -diameter spheres obtained with holographic characterization and with DLS for the same colloidal mixture used for Fig. 2. The two measurement techniques agree well with the manufacturer’s specification at . Holographic characterization also reports consistent results down to concentrations as low as . DLS, by contrast, deviates substantially from the correct value at lower concentrations. Similar concentration-dependent deviations in DLS results have been reported previously [38, 32].
3.3 Differentiating contaminants in a heterogeneous sample
The data in Fig. 4 illustrate how the size- and refractive-index data provided by particle-resolved holographic characterization can be used to differentiate different types of colloidal contaminants simultaneously dispersed in water. The model sample in this case contains a combination of polystyrene spheres, which resemble waterborne latex microbeads, as well as oil emulsion droplets and bacteria. Holographic characterization data for the three independent component samples are presented in Fig. 4(a) through Fig. 4(c).
The data for polystyrene microbeads in Fig. 4(a) show a small range of particle diameters and refractive indexes. The mean refractive index is consistent with that of polystyrene [18]. Silicone oil emulsion droplets are drawn from a much broader distribution of sizes, as can be seen in Fig. 4(b), but have a comparably narrow range of refractive indexes. This distribution, characteristic of emulsions, reflects the fact that each droplet has a homogeneous composition that is independent of size.
Bacteria, shown in Fig. 4(c), display substantially more variation in optical properties with size. The most probable refractive index, , at a diameter around is consistent with results of previous studies [24]. Smaller bacteria display higher effective refractive indexes because their light scattering properties are more strongly influenced by their high-index membranes [25]. Larger, older bacteria have lower apparent refractive indexes because their rod-like morphology distorts their holograms, as can be seen in Fig. 4. Fitting such holograms to the Lorenz-Mie theory for spheres has been shown to yield reliable values for the semi-major axis, but systematically lower values for the effective refractive index [40]. The observed distribution of properties, nevertheless, is characteristic of rod-like samples in suspension [39].
The mixture of microbeads, oil emulsion and bacteria presented in Fig. 4(d) is intended to illustrate the utility of holographic characterization for assessing the nature and quantity of contaminants in wastewater. The three different populations’ holographic signatures are clearly distinguishable in the joint distribution of particle size and refractive index. To the best of our knowledge, no other particle-characterization technique provides the information needed to simultaneously analyze multiple components that make up such a heterogenous system.
Holographic characterization cannot distinguish different types of particles that have the same size and the same refractive index. Such an overlap is apparent in Fig. 4(d) for -diameter particles with a refractive index around . In some cases, such degeneracies can be lifted by considering particle morphology [40, 39] as well as size and refractive index. This information also can be extracted from single-particle holograms, albeit at the cost of additional computational analysis [8, 13, 40, 39]. Fig. 5 illustrates this additional capability of holographic characterization through a comparison among typical holograms recorded for a polystyrene microbead (Fig. 4(a)), an oil droplet (Fig. 4(b)) and a bacterium (Fig. 4(c)). The rod-like morphology of the bacterium is evident in the uniaxial distortion of its hologram. Even without considering morphology, however, the presence of multiple overlapping populations in Fig. 4 can be inferred from trends in the distribution of properties in the plane.
3.4 Monitoring time-dependent concentrations
A typical distribution of particle properties, such as the example in Fig. 6(a) can be built up, particle-by-particle, over the course of ten minutes. Any pattern of clustering in the distribution can serve as a template for differentiating the detected particles into different categories. The sample in Fig. 6(a), for example, displays the three clusters of points, distinguished by color, that are characteristic of monodisperse polystyrene microbeads, oil emulsion droplets and bacteria. Each data point, therefore, can be assigned a category as it arrives and used to compute the rate of arrival of that type of particle. This rate, in turn, yields an estimate for the instantaneous concentration for that category.
The traces in Fig. 6(b) chronicle the arrival rate of microbeads, oil droplets and bacteria in an sample stream that was deliberately modified in three stages to illustrate the monitoring capabilities of holographic characterization. Initially, the sample consisted only of a suspension of microbeads, with a mean arrival rate of , which corresponds to a concentration of . After , silicone oil emulsion was injected into the flow. The observed concentration of oil droplets soon rises to while the concentration of microbeads decreases slightly due to dilution. This process is repeated after with the addition of bacteria. The observed concentration of bacteria rises shortly thereafter, as the concentrations of oil droplets and microbeads both diminish. Finally, more microbeads are added to the stream at , increasing their total concentration to . Both bacteria and oil droplets are diluted by the added volume of solvent, and their concentrations decline.
This proof-of-principle measurement demonstrates that time-resolved holographic characterization can be used to track the concentrations of multiple components independently and simultaneously in heterogeneous sample streams. This unique capability of holographic characterization should be useful for monitoring wastewater quality and for identifying changes in solvent reclamation processes.
The quality of the differentiation depends on the sophistication of the classification scheme. As many as of the bacteria may have been misclassified as oil droplets by the simple rectangular classification scheme used in Fig. 6. A smaller percentage of oil droplets might have been misclassified as bacteria. Additional data, such as morphological information, can be brought into consideration for cases where even more stringent differentiation is required.
3.5 Real-world samples: Distinguishing crude oil emulsions
Holographic particle characterization offers insights into the nature of waterborne contaminants that can be useful for identifying the nature of the contamination. Fig. 7 shows holographic characterization results for aqueous emulsions of three different types of crude oil: Pennsylvania light (Fig. 7(a)), Bryan Mound sweet MLI001 (Fig. 7(b)) and Basrah light OGJ 99 (Fig. 7(c)). Crude oil being a complex material, the emulsion droplets display a complicated distribution of properties. In all three cases, the majority of droplets are drawn from a relatively narrow distribution of refractive indexes. This characteristic refractive index, moreover, is quite distinct for the three types of oil. Pennsylvania light crude has the lowest characteristic refractive index, . Droplets of Bryan Mound sweet scatter light more strongly, and have a significantly high characteristic refractive index, . Basrah light crude has the highest refractive index, . The horizontal dashed lines in Fig. 7 indicate these three values, and demonstrate that the three types of oil have easily distinguishable properties.
Light scattering by the smallest detectable particles is strongly influenced by their surface properties. Natural surfactants and surface-bound nanoparticles therefore contribute to the large spread in measured refractive indexes for the smallest particles, both above and below the characteristic value. Characteristic refractive indexes are most readily determined, therefore, by considering larger particles whose refractive indexes are dominated by their bulk properties.
The small proportion of high-index particles outside of the main distributions in Fig. 7 may reflect the influence of strongly absorbing soot-like components of the oil. A detailed analysis of these contaminants’ influence on crude oil’s holographic signature would be an interesting subject for future study.
4 Conclusions
We have demonstrated the use of holographic video microscopy for analyzing micrometer-scale colloidal particles dispersed in aqueous media. Fitting holograms of individual particles to predictions of the Lorenz-Mie theory of light scattering yields measurements of the size and refractive index of each particle passing through the sample volume. This information can be used to differentiate colloidal particles by composition and morphology as well as by size. The accuracy and precision of holographic characterization data are verified through validation measurements on particle-sizing standards with independently specified characteristics. Tracking the detection of individual particles in a known volume of flowing fluid yields measurements of the concentrations of each particle species in a sample. We demonstrate this capability with a model system composed of a mixture of latex microbeads, oil emulsion droplets and bacteria that is intended to resemble the effluent wastewater from petroleum refining. Holographic characterization successfully distinguishes the different types of colloidal particles in this heterogeneous dispersion and independently monitors their concentrations. These results illustrate the potential value holographic characterization for monitoring the quality of wastewater produced by a wide range of industrial and natural processes.
Acknowledgements
This work was supported by the SBIR program of the National Science Foundation under grant number IIP-1519057 and the Higher Committee for Education Development (HCED) in Iraq.
References
References
- [1] (1999) Particle characteristics: a key factor in effluent treatment and reuse. Water Sci. Technol. 40 (4-5), pp. 67–74. Cited by: §1.
- [2] (1982) Local-field effects and effective-medium theory: a microscopic perspective. American Journal of Physics 50, pp. 704–709. Cited by: §2.1.6.
- [3] (2004) E. coli in motion. Springer-Verlag, New York. Cited by: §2.2.3.
- [4] (1983) Absorption and scattering of light by small particles. Wiley Interscience, New York. Cited by: §1, §2.1.2.
- [5] (2006) Bacterial communities in industrial wastewater bioreactors. Curr. Opin. Microbio. 9 (3), pp. 275–278. Cited by: §1.
- [6] (2007) Characterizing and tracking single colloidal particles with video holographic microscopy. Optics Express 15, pp. 18275–18282. External Links: 0712.1738, Document Cited by: §1, §1, §2.1.4.
- [7] (2007) Holographic microscopy of holographically trapped three-dimensional structures. Optics Express 15, pp. 1505–1512. External Links: Document Cited by: §1.
- [8] (2010) Rotational and translational diffusion of copper oxide nanorods measured with holographic video microscopy. Optics Express 18, pp. 6555–6562. External Links: Document Cited by: §3.3.
- [9] (2009) Flow visualization and flow cytometry with holographic video microscopy. Optics Express 17, pp. 13071–13079. External Links: Document Cited by: §1, §2.1.1, §2.1.1, §2.1.4.
- [10] (2011) Holographic characterization of individual colloidal spheres’ porosities. Soft Matter 7, pp. 6816–6819. External Links: Document Cited by: §2.1.4, §2.1.6.
- [11] (1996) Methods of digital video microscopy for colloidal studies. Journal of Colloid and Interface Science 179, pp. 298–310. External Links: Document Cited by: §2.1.1.
- [12] (2007) Global onshore and offshore water production. Oil and Gas Review, OTC edition. Cited by: §1.
- [13] (2011) Holographic deconvolution microscopy for high-resolution particle tracking. Optics Express 19, pp. 16410–16417. External Links: Document Cited by: §3.3.
- [14] (2011) Holographic particle-streak velocimetry. Optics Express 19, pp. 4393–4398. External Links: Document Cited by: §2.1.1.
- [15] (1999) Dynamic light scattering. American Journal of Physics 67 (12), pp. 1152–1160. Cited by: §1.
- [16] (2015) Holographic characterization of imperfect colloidal spheres. Applied Physics Letters 107, pp. 141905. External Links: 1508.01710, Document Cited by: §2.1.4, §2.1.6.
- [17] (2013) Pharmaceutical feasibility of sub-visible particle analysis in parenterals with reduced volume light obscuration methods. Eur. J. Pharm. Biopharm. 85 (3), pp. 1084–1087. Cited by: §1.
- [18] (2007) Analysis of the dispersion of optical plastic materials. Opt. Mat. 29, pp. 1481–1490. Cited by: §2.1.1, §3.3.
- [19] (2004) Prediction of oil droplet size distribution in agitated aquatic environments. In Artic and Marine Oilspill Program (AMOP) Technical Seminar, Vol. 1, pp. 1046. Cited by: §1.
- [20] (2002) Crude oil emulsions: a state-of-the-art review. In SPE Annual Technical Conference and Exhibition, pp. 5–13. Cited by: §1.
- [21] (2014) Measuring Boltzmann’s constant through holographic video microscopy of a single sphere. American Journal of Physics 82, pp. 23–31. External Links: Document Cited by: §2.1.4.
- [22] (1985) Characterization of the size distribution of contaminants in wastewater: treatment and reuse implications. Water Pollution Control Federation, pp. 805–816. Cited by: §1.
- [23] (1991) Size distributions of particulate contaminants in wastewater and their impact on treatability. Water Res. 25 (8), pp. 911–922. Cited by: §1.
- [24] (2016) Cell refractive index for cell biology and disease diagnosis: past, present and future. Lab on a Chip 16, pp. 634–644. Cited by: §3.3.
- [25] (2014) Real-time measurement of single bacterium’s refractive index using optofluidic immersion refractometry. Procedia Engineering 87, pp. 356–359. Cited by: §3.3.
- [26] (2009) Non-linear least squares fitting in IDL with MPFIT. In Astronomical Data Analysis Software and Systems XVIII, D. Bohlender, P. Dowler and D. Durand (Eds.), San Francisco, pp. 251–254. Cited by: §2.1.2.
- [27] (2001) Scattering, absorption and emission of light by small particles. Cambridge University Press, Cambridge. Cited by: §1, §2.1.2.
- [28] (2016) Wastewater treatment works (WwTW) as a source of microplastics in the aquatic environment. Environmental Science & Technology 50, pp. 5800–5808. Cited by: §1.
- [29] (1996) Wastewater characteristics. Resour. Conserv. and Recycl. 16 (1), pp. 145–159. Cited by: §1.
- [30] (2012) Effect of finite terms on the truncation error of Mie series. Optics Letters 37, pp. 2418–2420. Cited by: §2.1.2.
- [31] (2004) Effluent guidelines program plan. Technical report Technical Report EPA-821-R-04-014, U.S. Environmental Protection Agency. Cited by: §2.1.5.
- [32] (2014) Analyzing subvisible particles in protein drug products: a comparison of dynamic light scattering (DLS) and resonant mass measurement (RMM). AAPS J. 16 (3), pp. 440–451. Cited by: §3.2.
- [33] (2009) Scattering of electromagnetic radiation by a layered sphere. Comp. Phys. Commun. 180, pp. 2348–2354. Cited by: §2.1.2.
- [34] (2011) The coulter principle for analysis of subvisible particles in protein formulations. AAPS J. 13 (1), pp. 54–58. Cited by: §1.
- [35] (2010) Micro-flow imaging: flow microscopy applied to sub-visible particulate analysis in protein formulations. AAPS J. 12 (3), pp. 455–464. Cited by: §1.
- [36] (2006) Digital holographic microscope for measuring three-dimensional particle distributions and motions. Applied Optics 45 (16), pp. 3893–3901. Cited by: §1.
- [37] (2012) Holographic microrefractometer. Applied Physics Letters 101, pp. 091102. External Links: Document Cited by: §2.1.4.
- [38] (2013) Detection limits of dls and uv-vis spectroscopy in characterization of polydisperse nanoparticles colloids. J. Nanomater. 2013, pp. 60. Cited by: §3.2.
- [39] (2016) Holographic characterization of colloidal fractal aggregates. Soft Matter 12, pp. 8774–8780. External Links: Document Cited by: §2.1.4, §2.1.6, §3.3, §3.3.
- [40] (2016) Holographic characterization of protein aggregates. Journal of Pharmaceutical Sciences 105, pp. 1074–1085. External Links: Document Cited by: §2.1.4, §2.1.6, §3.3, §3.3.
- [41] (2014) Light obscuration measurements of highly viscous solutions: sample pressurization overcomes underestimation of subvisible particle counts. AAPS J. 16 (5), pp. 1128–1131. Cited by: §1.
- [42] (1980) Improved Mie scattering algorithms. Applied Optics 19, pp. 1505–1509. Cited by: §2.1.2.
- [43] (2001) Particle characterization: light scattering methods. Particle Technology Series, Kluwer Academic Publishers, Dordrecht. Cited by: §1.
- [44] (2015) Light scattering: a review of particle characterization applications. Particuology 18, pp. 11–21. Cited by: §1.
- [45] (2003) Improved recursive algorithm for light scattering by a multilayered sphere. Applied Optics 42, pp. 1710–1720. Cited by: §2.1.2.
- [46] (2014) Machine-learning approach to holographic particle characterization. Optics Express 22, pp. 26884–26890. External Links: Document Cited by: §1.
- [47] (2013) A review of treating oily wastewater. Arabian Journal of Chemistry (in press). External Links: Document Cited by: §1, §2.1.5.